Weighing Systems PIA AXLE/W
Download PDF datasheetWeighing system consists of 2/3/4 modular and portable platforms with touch screen indicator in ABS portable suitcase. Low profile and high flow rates platforms, sturdily built in alloy anodized white aluminum material. Double up/down ramp with a wide support base for immediate vehicle placement. Carrying handles equipped. Individual display of each single platform or the sum of all with total weight and partial axes display. Platforms-indicator connection system by radio transmitter and receiver. The display comes in handy and durable carrying case to transport.
Indicator model WINTS: high-contrast monochrome TOUCH SCREEN system, capable to view and print each wheel of each axle weight, print each diagonal sum and total weight. For each control type of the weights distribution in running position. Power by internal rechargeable batteries, supplied with charger, battery duration 200h. Acquisition through integrated wireless communication.
Click on the image to enlarge
Technical specifications
| Power supply | 220 V ac / 24 V dc |
|---|---|
| Operating temperature | -10 / +50 °C (14 / 122 °F) umidità Massimo 85% senza condensa) |
| Storage temperature | -20 / +60°C (-4 / +140°F) |
| Display | LCD 5.2 "(visible area 118 x 58 mm) monochromatic high contrast |
| Display brightness | White LEDs, adjustable intensity |
| Touch screen | Resistive 4 wires, suitable for use with gloves, buzzer |
| Overall dimensions | 600x420x53 mm (600x527mm lato inferiore) |
| Frequency | 866-868 MHz |
| Num. RF Channels | 7 selectable by DIP switch |
| Num. Network address | 15 selectable by DIP switch |
| Average radius of coverage | 50 m (165 feet) |
| Average battery life | ~200 h |
| Platform weight | 25 kg / 55 lbs |
| Load cells material | Stainless steel |
| Load cells capacity | 2,5t 5t 10t |
| Cells number (1 platform) | 6 |
| Briefcase overall dimensions | 400 x 300 x 200 mm / 15.7 x 11.8 x 7.9 in |
| Briefcase weight | 5 kg / 11 lbs |
For complete and up-to-date technical specifications please refer to the datasheet you can download here
Download PDF datasheetLoad cell mounting
General guidelines for installing and mounting load cells:
- Respect the direction in which forces are applied to the load cells
- Do not exceed the temperature limits shown on the rating plate
- Do not remove the labels from the cells
- Protect cables properly with sheaths or cable ducts
- Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
- Do not weld on the mechanical structure once the cells are in place
- Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
- When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
- Protect the cells from dust build-up with suitable covers